Operation
©
2017 Sensata Technologies
Page 55
5.1.3
ON/OFF Buttons
• ON/OFF
INVERTER:
This button toggles the inverter function on and off. The green INV LED
turns on and off with the button.
• ON/OFF
CHARGER:
This button toggles the charger function on and off after it is actively
charging. This button is also used to initiate an Equalize charge. See Section 5.2.2 for more
info on using the Equalize charge feature (see Equalizing mode info on pages
60-61).
5.1.4
Menu Buttons
These
fi
ve buttons provide quick access to menu items for con
fi
guring, monitoring, and
troubleshooting your inverter/charger system.
• PORT:
This button scrolls through the active communication ports (P1-P6). Pressing the PORT
button skips over non-active or empty ports allowing quick access to connected devices.
• CTRL:
This button contains the
AC In Control
,
Charger Control
,
Gen Control
,
ARTR Aux Relay,
and
PT Control
menus. The CTRL button gives you quick control of the main functions of the
inverter/charger.
• METER:
This button provides meter information on the inverter/charger, and the ME-AGS-N
and ME-BMK/ME-BMK-NS (if connected). See Section 3.3.3 for more detailed information.
Info:
If the LCD display becomes unreadable, press and hold the METER button until
the System Home screen appears (~3 seconds) to refresh the LCD display.
• SETUP:
This button allows the router, the inverter/charger, and any connected accessory to
be con
fi
gured to your speci
fi
c system preferences. See Section 3.3.4 for more information.
• TECH:
This button allows you to access menu selections that can help service personnel with
troubleshooting, and also allows the factory default settings for the inverter/charger and any
connected accessory to be restored. See Section 3.3.5 for more information.
5.1.5
Rotary SELECT Knob
The rotary SELECT knob is used to view and select various menu items and settings displayed on
the LCD screen. Turn clockwise/counterclockwise to view the different menu items and available
settings. Press the SELECT knob to select/enter a menu item or to save a setting once it is
displayed on the LCD screen.
Info:
All adjustable settings in the router (except for
SETUP:
01B Screen Setup
,
CTRL:
03 Gen Control
and
TECH: 08 Show all Menus
—which revert back to default) are saved
in non-volatile memory and are preserved until changed—even if an inverter reset is
performed or if all power to the router or inverter is removed.
CAUTION:
An accessory that is networked to the inverter may have adjustable settings
that revert back to default if all power to the inverter is lost. Refer to the owner’s
manual for the particular accessory to determine if any setting is affected.
Aux Relay LED Indicator
Figure 5-2, Aux Relay LED
5.1.6
Aux Relay LED Indicator
The yellow Aux LED indicator allows a visual indication of
the Aux Relay’s operation. The LED will be ON when the
relay is disengaged (energized), and will be OFF when the
relay is engaged (de-energized). See Figure 5-2.
What is the Aux Relay used for?
Commonly used to turn
on an exhaust fan to eliminate your battery bank gasses
per the VDC start and stop settings. The Aux Relay can also
be used to control the coil of a current carrying relay.
How do I adjust the Aux Relay?
The
SETUP: 01F ARTR
Aux Relay
and
01G ARTR Relay SOC
menus are used to
determine the conditions (DC volts, inverter fault, or
battery SOC) at which the relay automatically engages and
disengages.