Setup
©
2017 Sensata Technologies
Page 43
SETUP: 05 BMK Setup
The ME-BMK/ME-BMK-NS (Battery Monitor Kit) accurately measures the SOC (State Of Charge),
battery voltage, and the DC amps of the battery bank. Refer to Section 9.0 “Using a BMK” for
detailed information on the available BMK menus using the router.
Info:
For installation information on the ME-BMK/ME-BMK-NS, refer to your BMK
owner’s manual (PN: 64-0013)
.
SETUP: 06 RC Setup
A remote control can be connected to the router and used to monitor your system. Refer to
Section 10.0 “Attaching a Remote Control” for information on the available remote control menus
using the router.
Info:
For additional information on the ME-RC or ME-ARC remote controls, refer to your
remote’s owner’s manual (PN: 64-0003 for a ME-RC; PN: 64-0030 for a ME-ARC)
.
SETUP: 07 PT Setup
A PT-100 charge controller can be setup using the router. Refer to Section 12.0 “Using a PT
Controller” for information on the available remote control menus using the router.
Info:
For additional information on the PT-100, refer to the PT-100’s owner’s manual
(PN: 64-0067)
.
3.3.5
TECH Button and Menus
The TECH menu button provides access to selections that assist service technicians in
troubleshooting. It also provides access to system information, allows you to update the router’s
fi
rmware, and provides an option to return all system settings to the original factory default
values. See Figure 3-17 below.
Press to edit
setting if
available
Press
TECH
Rotate to
desired
selection:
Top line shows menu
Bottom line shows port
and menu item
01A INV BTS Temp
1 82F 2 ---- 3 ----
4 ---- 5 ---- 6 ----
ALL Read TECH
...
...
01 Temperatures
Press SELECT
ALL View TECH
05 Fault History
Press SELECT
ALL View TECH
10 Load All Defaults
Press & hold SELECT
knob to Load in 5.0
ALL View TECH
Figure 3-17, TECH Button
TECH: 01 Temperatures
The TECH button’s
fi
rst menu displays temps of ALL the units connected to the router. The units
display in the order of the port# to which they are connected (1-6). Temperatures displayed are:
• 01A INV
BTS Temp
– Displays the temperature of each inverter’s Battery Temp Sensor
(BTS) that is connected to the battery bank.
• 01B INV Tfmer Temp
– Displays the temperature of each inverter’s main power transformer.
• 01C INV FETs Temp
– Displays the temperature of each inverter’s Field Effect Transistors
(FET).
Info:
The temperatures are displayed in Celsius or Fahrenheit, as selected in the
SETUP menu’s
01D Temp Display
setting.
Note:
You can view all three of the above temperature readings on a single port-speci
fi
c display
for each connected inverter (see example below).