Starting up the device - CANopen interface
Leuze electronic GmbH + Co. KG
CML 730i
99
General configurations (group 3)
Extended settings (group 4)
Parameter
Index
(hex.)
Sub-
index
(hex.)
Data
type
Access
Min.
value
Max. value Default Explanation
Manufacturer name
2000
RO
Leuze electronic
Manufacturer text
2001
RO
The sensor people
Receiver part no.
2002
RO
Receiver
Receiver serial number
2003
RO
Receiver
Transmitter product designation
2008
RO
Transmitter
Transmitter part no.
2009
RO
Transmitter
Transmitter serial number
200A
RO
Transmitter
Beam spacing
200B
1
t16U
RO
Number of physical individual beams
200B
2
t16U
RO
Number of configured logical cascades
200B
3
t16U
RO
With parallel scanning, the
number of logical individual
beams corresponds to the
number of physical individual
beams; with diagonal scan
-
ning, this number is doubled.
Number of optical cascades
200B
4
t16U
RO
Device cycle time [µs]
200B
5
t16U
RO
Duration for a complete mea
-
surement cycle (measure
-
ment cycle for one
measurement); minimum time
is 1 ms.
Configured in group 3 “General configurations” are the type of scanning (parallel-/diagonal-/
crossed-beam), counting direction and minimum object size for the evaluation (smoothing). The
minimum hole size for the evaluation, e.g., with web material, is configured via inverted smooth
-
ing.
Parameter
Index
(hex.)
Sub-
index
(hex.)
Data
type
Access
Min.
value
Max. value Default Explanation
Operating mode
2100
1
t08U
RW
0
2
0
0: Parallel-beam scanning
1: Diagonal-beam scanning
2: Crossed-beam scanning
Counting direction
2100
2
t08U
RW
0
1
0
0: Normal – beginning at the
connection side
1: Inverted – beginning oppo
-
site the connection side
Smoothing
2100
3
t08U
RW
1
MAX_T08U 1
Less than i interrupted beams
are ignored
Smoothing inverted
2100
4
t08U
RW
1
MAX_T08U 1
Less than i free beams are
ignored
The filter depth indicates the necessary number of consistent beam states before the evaluation
of the measurement values.
All measurement values are accumulated and retained over the duration of the integration time.