Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
131
13.4.3 DAP module
The PROFINET Device Access Point module (DAP module) represents the communication access point
to the CML 700i.
• The DAP module is automatically and permanently plugged in at slot 0.
• The DAP module does not have any input and output data or any device-specific parameters.
13.4.4 Sensor control module (module 00)
The sensor control module allows to control the CML 700i via the process data with byte 1 and byte 2. In
both cases, the command is triggered in the device by changing (e.g. incrementing) the data value.
• Module ID: 1000
• Submodule ID: 1
13.4.5 First interrupted beam (module 01)
The module allows evaluation of the CML 700i information regarding the first interrupted beam (FIB).
• Module ID: 1001
• Submodule ID: 1
13.4.6 First not interrupted beam (module 02)
The module allows evaluation of the CML 700i information regarding the first not interrupted beam (FNIB).
• Module ID: 1002
• Submodule ID: 1
13.4.7 Last interrupted beam (module 03)
The module allows evaluation of the CML 700i information regarding the last interrupted beam (LIB).
• Module ID: 1003
• Submodule ID: 1
Output data
Rel.
address
Data type
Value range
Default Explanation
Activate trigger
(Minimum time gap ≥ 10 ms
Smaller values are ignored under
certain circumstances)
0
Unsigned 8
0 … 255
0
Changing the data value causes a trigger to be acti
-
vated.
Trigger teach
1
Unsigned 8
0 … 255
0
Changing the data value causes a teach to be trig
-
gered.
Output data length: 2 bytes
Input data
Rel.
address
Data type
Value range
Default Explanation
Beam number
0
USIGN 16
0 … 1774
0
Number of the first interrupted beam
Input data length: 2 byte consistently
Input data
Rel.
address
Data type
Value range
Default Explanation
Beam number
0
USIGN 16
0 … 1774
0
Number of the first not interrupted beam
Input data length: 2 byte consistently
Input data
Rel.
address
Data type
Value range
Default Explanation
Beam number
0
USIGN 16
0 … 1774
0
Number of the last interrupted beam
Input data length: 2 byte consistently