Starting up the device - PROFIBUS interface
Leuze electronic GmbH + Co. KG
CML 730i
117
12.4.13 General settings (module 11)
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Parameter
0
Unsigned8
0 … 255
0 … 161
0
0: ZERO
16: Manufacturer
17: Manufacturer text
18: Receiver product designation
19: Receiver part no.
20: Product description
21: Receiver serial number
22: Hardware version
23: Firmware version
24: Application-specific name
64: Transmitter product designation
65: Transmitter part no.
66: Transmitter serial number
67: Device description
68: Teach status
69: Status - alignment
70: General settings
71: Process data configuration
72: Cascading configuration
73: Extended settings
75: Blanking area configuration
76: Digital PNP/NPN
80: Digital IO 01
81: Digital IO 02
82: Digital IO 03
83: Digital IO 04
84: Digital output 01
85: Digital output 02
86: Digital output 03
87: Digital output 04
88: Analog output configuration
89: Analog function
100: Area 01
101: Area 02
102: Area 03
…
129: Area 30
130: Area 31
131: Area 32
150: 1st interrupted beam
151: 1st not interrupted beam
152: Last interrupted beam
153: Last not interrupted beam
154: Total of interrupted beams
155: Total of not interrupted beams
158: Status of areas 16 … 1
159: Status of areas 32 … 17
160: Status of digital inputs/outputs
161: Status of analog output
Under general settings, the type of scanning (parallel-/diagonal-/crossed-beam), counting direc
-
tion and minimum object for evaluation (smoothing) or minimum hole size (inverted smoothing)
are set.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Operating mode
0
BitArea(4 … 7)
0 … 3
0 … 2
0
0: Parallel-beam scanning
1: Diagonal-beam scanning
2: Crossed-beam scanning
Counting direction
0
Bit(0)
0 … 1
0 … 1
0
0: Normal (interface → )
1: Inverted ( → interface)
Smoothing
1
Unsigned8
1 … 255
1
Smoothing:
Less than i interrupted beams are ignored.
Inverted smoothing
2
Unsigned8
1 … 255
1
Inverted smoothing:
Less than i free beams are ignored.