Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
135
Beam-stream 4 (128 bit) (module 23)
• Module ID: 1023
• Submodule ID: 1
Beam-stream 5 (256 bit) (module 24)
• Module ID: 1024
• Submodule ID: 1
Beam-stream 6 (512 bit) (module 25)
• Module ID: 1025
• Submodule ID: 1
Input data
Rel.
address.
Data type
Value range
Default Explanation
Beam-stream data
0
USIGN 64
Bit 0 … 63
0: Beam inter
-
rupted
1: Beam not
interrupted
0
Transmits 64 logical beams beginning with the con
-
figured optical cascade.
Input data length: 8 byte
Parameter
Rel.
address.
Data type
Value range
Default Explanation
Number of the optical cascade
0
USIGN 8
1 … 104
1
Beam number multiplied by 16, beginning with
which the beam-stream data is to be transmitted.
Start value: 1+(i-1)*16
Parameter length: 1 byte
Input data
Rel.
address.
Data type
Value range
Default Explanation
Beam-stream data
0
USIGN 128
Bit 0 … 127
0: Beam inter
-
rupted
1: Beam not
interrupted
0
Transmits 128 logical beams beginning with the
configured optical cascade.
Input data length: 16 byte
Parameter
Rel.
address.
Data type
Value range
Default Explanation
Number of the optical cascade
0
USIGN 8
1 … 96
1
Beam number multiplied by 16, beginning with
which the beam-stream data is to be transmitted.
Start value: 1+(i-1)*16
Parameter length: 1 byte
Input data
Rel.
address.
Data type
Value range
Default Explanation
Beam-stream data
0
USIGN 256
Bit 0 … 255
0: Beam inter
-
rupted
1: Beam not
interrupted
0
Transmits 256 logical beams beginning with the
configured optical cascade.
Input data length: 32 byte
Parameter
Rel.
address.
Data type
Value range
Default Explanation
Number of the optical cascade
0
USIGN 8
1 … 80
1
Beam number multiplied by 16, beginning with
which the beam-stream data is to be transmitted.
Start value: 1+(i-1)*16