Electrical connection
Leuze electronic GmbH + Co. KG
CML 730i
55
Connection cables: see table 21.3.
7.5.2 X1 pin assignment – CML 700i with analog interface
8-pin, M12 connector (A-coded) is used for connecting to PWR IN/digital IO and analog interface.
1
M12 connector (8-pin, A-coded)
Figure 7.7: X1 connection – CML 700i with analog interface
Table 7.3:
X1 pin assignment – CML 700i with analog interface
Connection cables: see table 21.3.
5
IO 2: input/output (configurable)
Ex works: trigger input (Trigger-In)
6
IO 3: input/output (configurable)
7
IO 4: input/output (configurable)
8
GND: ground (0 V)
Pin
X1 - Logic and power on the receiver
1
Pin
X1 - Logic and power on the receiver
1
VIN: +24 V DC supply voltage
2
IO 1: input/output (configurable)
Ex works: teach input
3
GND: ground (0 V)
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
Ex works: trigger input
6
IO 3: input/output (configurable)
Ex works: validation output
7
Toggling:
• Analog voltage output (0 … 10 V)
• Analog current output (4 … 20 mA)
8
AGND: analog output reference potential
NOTICE
Select either voltage output or current output (pin 7)!
Voltage output and current output (pin 7) are not available simultaneously. The type of analog signal
must be selected via the receiver control panel (see chapter 9). Alternatively, the analog signal can be
configured via the
Sensor Studio