Figure 16.4: Device selection for CML 700i measuring light curtain
Select the connected light curtain according to the configuration in the Device Selection and click on
[Next].
In the devicedescription in the device selection list, the values for the bit rate and PD length configura
-
tion parameters for the respective light curtain are listed. Factory settings on delivery:
Bit rate: COM2
PD length: 2 bytes
The device manager (DTM) of the connected light curtain starts with the offline view for the
Sensor Studio
configuration project.
Establish the online connection to the connected light curtain.
In the
Sensor Studio
FDT frame, click on the [Establish connection with device] button (
).
In the
Sensor Studio
FDT frame, click on the [Online parameters] button (
).
The IO-Link USB master synchronizes with the connected light curtain and the current configuration data
and process data are displayed in the device manager (DTM).