Technical data
Leuze electronic GmbH + Co. KG
CML 730i
203
Table 20.9:
Mechanical data
Table 20.10:
Environmental data
Table 20.11:
Certifications
20.2 Time behavior
In principle, the individual beams are always processed sequentially for light curtains. The internal
controller starts transmitter 1 and then activates only the corresponding receiver 1 to measure the received
light power. If the measured value exceeds the switch-on threshold, this first beam is evaluated as an unin
-
terrupted/free beam.
The time between activation of the transmitter and evaluation in the receiver is referred to as the response
time per beam.
In the CML 730i the response time per beam is = 10 µs.
The total cycle time for the evaluation of all beams and transmission to the interface is calculated as
follows:
Activation delay
≤ 1 ms
Input resistance
Approx. 6 k Ω
Analog interfaces
0 … 10(11) V and 0(4) … 20(24) mA
Digital interfaces
IO-Link (230.4 kbit/s; 38.4 kbit/s)
CANopen (max. 1 Mbit/s)
PROFIBUS (max. 3 Mbit/s)
PROFINET (max. 10/100 Mbit/s)
RS 485 Modbus (921 kbit/s)
Housing
Continuous-cast aluminum
Optics cover
PMMA plastic
Connection technology
M12 connectors
(8-pin / 5-pin)
Ambient temperature (operation)
-30 °C … +60 °C
Dry cold, non-condensing
Detection of transparent media to -20 °C
Ambient temperature (storage)
-40 °C … +70 °C
Protective circuit
Transient protection
Polarity reversal protection
Short circuit protection for all outputs (provide external
protective circuit for inductive load for this purpose!)
Degree of protection
IP 65
Protection class
III
Certifications
UL 508, CSA C22.2 No.14
Light source: exempt group (in acc. with EN 62471)
Standards applied
IEC 60947-5-2
Electromagnetic compatibility
IEC 61000-6-2 and EN 1000-6-4
Industrial interference emission
This is a Class A product. In a domestic environment, this
product may cause radio interference. In this case the
operator may be required to take appropriate measures.