Starting up the device - PROFIBUS interface
Leuze electronic GmbH + Co. KG
CML 730i
113
12.4.1 Module overview
12.4.2 Sensor control module (module 0)
Module no.
Module name
ID (hex) Parame
-
ter
Input
data
Output
data
Module 0
Sensor control module (see page 113)
C0
0
0
2
Module 1
Evaluation functions (16 bit) (see page 114)
F0
1
2
0
Module 2
Beam-stream (16 bit) (see page 114)
B0
1
2
0
Module 3
Beam-stream (32 bit) (see page 114)
B1
1
4
0
Module 4
Beam-stream (64 bit) (see page 115)
B2
1
8
0
Module 5
Beam-stream (128 bit) (see page 115)
B3
1
16
0
Module 6
Beam-stream (256 bit) (see page 115)
B4
1
32
0
Module 7
Beam-stream (512 bit) (see page 115)
B5
1
64
0
Module 8
Beam-stream (1024 bit) (see page 115)
B6
1
128
0
Module 9
Beam-stream (1774 bit) (see page 116)
B7
0
222
0
Module 10
Read device parameters (see page 116)
E0
1
0
0
Module 11
General settings (see page 117)
D0
3
0
0
Module 12
Extended settings (see page 118)
D1
4
0
0
Module 13
Configuration of digital I/Os (see page 118)
D2
16
0
0
Module 14
D3
3
0
0
Module 15
Cascading configuration (see page 119)
D4
7
0
0
Module 17
Blanking configuration (see page 120)
D6
21
0
0
Module 18
Autosplitting configuration (see page 121)
D7
1
0
0
Module 19
Area settings (see page 121)
D8
13
0
0
Module 20
Sensor command module (see page 122)
F1
0
4
4
The sensor control module allows to control the CML 700i via the process data with byte 1 and
byte 2. In both cases, the command is triggered in the device by incrementing the data value.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Sensor control module
Trigger = byte 1
Teach = byte 2