Starting up the device - PROFIBUS interface
Leuze electronic GmbH + Co. KG
CML 730i
115
12.4.6 Beam-stream (64 bit) (module 4)
12.4.7 Beam-stream (128 bit) (module 5)
12.4.8 Beam-stream (256 bit) (module 6)
12.4.9 Beam-stream (512 bit) (module 7)
12.4.10 Beam-stream (1024 bit) (module 8)
Reading out of the beam states of all existing individual beams. The object transmits 64 logical
beams beginning with the configured optical cascade. One bit is transmitted for each interrupted
or uninterrupted beam.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Number of the optical cascade
0
Unsigned64
1 … 108
1
Beam number multiplied by 16, beginning with which the
beam-stream data is to be transmitted.
Start value: 1+(i-1)*16
Reading out of the beam states of all existing individual beams. The object transmits 128 logical
beams beginning with the configured optical cascade. One bit is transmitted for each interrupted
or uninterrupted beam.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Number of the optical cascade
0
Unsigned128
1 … 104
1
Beam number multiplied by 16, beginning with which the
beam-stream data is to be transmitted.
Start value: 1+(i-1)*16
Reading out of the beam states of all existing individual beams. The object transmits 256 logical
beams beginning with the configured optical cascade. One bit is transmitted for each interrupted
or uninterrupted beam.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Number of the optical cascade
0
Unsigned256
1 … 96
1
Beam number multiplied by 16, beginning with which the
beam-stream data is to be transmitted.
Start value: 1+(i-1)*16
Reading out of the beam states of all existing individual beams. The object transmits 512 logical
beams beginning with the configured optical cascade. One bit is transmitted for each interrupted
or uninterrupted beam.
Parameter
Rel.
addr.
Data type
Value range
Default Explanation
Number of the optical cascade
0
Unsigned512
1 … 80
1
Beam number multiplied by 16, beginning with which the
beam-stream data is to be transmitted.
Start value: 1+(i-1)*16
Reading out of the beam states of all existing individual beams. The object transmits 1024 logical
beams beginning with the configured optical cascade. One bit is transmitted for each interrupted
or uninterrupted beam.