Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
136
Beam-stream 7 (1024 bit) (module 26)
• Module ID: 1026
• Submodule ID: 1
Beam-stream 8 (1774 bit) (module 27)
• Module ID: 1026
• Submodule ID: 1
13.4.17 General settings (module 30)
Under general settings, the type of scanning (parallel-/diagonal-/crossed-beam), counting direction and
minimum object for evaluation (smoothing) or minimum hole size (inverted smoothing) are set.
• Module ID: 1030
• Submodule ID: 1
Input data
Rel.
address.
Data type
Value range
Default Explanation
Beam-stream data
0
USIGN 512
Bit 0 … 511
0: Beam inter
-
rupted
1: Beam not
interrupted
0
Transmits 512 logical beams beginning with the
configured optical cascade.
Input data length: 64 byte
Parameter
Rel.
address.
Data type
Value range
Default Explanation
Number of the optical cascade
0
USIGN 8
1 … 48
1
Beam number multiplied by 16, beginning with
which the beam-stream data is to be transmitted.
Start value: 1+(i-1)*16
Parameter length: 1 byte
Input data
Rel.
address.
Data type
Value range
Default Explanation
Beam-stream data
0
USIGN 1024
Bit 0 … 1023
0: Beam inter
-
rupted
1: Beam not
interrupted
0
Transmits 1024 logical beams beginning with the
configured optical cascade.
Input data length: 128 byte
Parameter
Rel.
address.
Data type
Value range
Default Explanation
Number of the optical cascade
0
USIGN 8
1
1
Beam number multiplied by 16, beginning with
which the beam-stream data is to be transmitted.
Start value: 1+(i-1)*16
Parameter length: 1 byte
Input data
Rel.
address.
Data type
Value range
Default Explanation
Beam-stream data
0
USIGN 1774
Bit 0 … 1773
0: Beam inter
-
rupted
1: Beam not
interrupted
0
Transmits 1774 logical beams beginning with the
configured optical cascade.
Input data length: 222 byte