Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
133
13.4.13 Status digital inputs/outputs (module 09)
The module allows evaluation of the CML 700i status information regarding the digital inputs/outputs.
• Module ID: 1009
• Submodule ID: 1
13.4.14 Status of CML 700i (module 10)
The module allows evaluation of the CML 700i status information.
• Module ID: 1010
• Submodule ID: 1
13.4.15 CML 700i detailed status information (module 11)
The module allows evaluation of the structured CML 700i status codes.
• Module ID: 1011
• Submodule ID: 1
Input data
Rel.
address
Data type
Value range
Default Explanation
Status
0
USIGN 16
0 … 65535
0
Status of beam areas 32 to 17
0: Beam area logical LOW
1: Beam area logical HIGH; switching condition ful
-
filled
Input data length: 2 byte consistently
Input data
Rel.
address
Data type
Value range
Default Explanation
Status
0
USIGN 16
0 … 3
• Bit 0: IO 1
• Bit 1: IO 2
0
Logical status of the digital inputs/outputs
Input data length: 2 byte consistently
Input data
Rel.
address
Data type
Value range
Default Explanation
Status
0
USIGN 16
Bits 0 … 11:
measurement
cycle number of
a measurement
Bits 12 … 14:
reserved
Bit 15:
1: Valid measu
-
rement result
exists.
0
CML 700i status information
Input data length: 2 byte consistently
Input data
Rel.
address
Data type
Value range
Default Explanation
Status
0
USIGN 16
Bit 0 … 13:
Detailed status
code
Bit 14: 1 = Event
(is set if status
changes. As
soon as the sta
-
tus is 0 again,
bit 14 is also set
to 0.)
Bit 15:
1: Valid measu
-
rement result
exists.
0
Detailed CML 700i status information
Input data length: 2 byte consistently