Starting up the device - PROFIBUS interface
Leuze electronic GmbH + Co. KG
CML 730i
111
12
Starting up the device - PROFIBUS interface
The configuration of a PROFIBUS interface involves the following steps on the receiver control panel and
in the control-specific configuration software.
General prerequisites:
• The measuring light curtain has been mounted (see chapter 6) and connected (see chapter 7) cor
-
rectly.
• The basic configuration has been performed (see chapter 8).
12.1 Defining the PROFIBUS basic configuration on the receiver control panel
The parameters for the PROFIBUS interface are defined with the slave address and bit rate configurations.
The structure of these configurations in the receiver control panel menu is as follows:
Prerequisites:
• The measuring light curtain must be correctly aligned (see chapter 8.1).
• The measuring light curtain must be correctly taught (see chapter 8.2).
The following procedure describes the configurations for PROFIBUS interfaces.
Select Main Settings > PROFIBUS > Slave Address > Enter value.
Select Main Settings > PROFIBUS > Bit rate > Enter value.
The bus address and bit rate are configured.
Other possible configuration steps are performed via the
Sensor Studio
configuration software (see
chapter 16).
Process mode is configured via the control-specific PROFIBUS interface.
12.2 Defining configurations via the PLC-specific software
General prerequisites:
• The measuring light curtain has been mounted (see chapter 6) and connected (see chapter 7) cor
-
rectly.
• The basic configuration has been performed (see chapter 8).
• The PROFIBUS basic configurations have been performed:
• Slave address selected
• Bit rate selected
Specific prerequisites:
• The PROFIBUS-specific GSD file must be installed on the control.
Level 0
Level 1
Level 2
Description
Main Settings
Commands
Operation settings
IO-Link
PROFIBUS
Slave Address
(enter value)
min = 1
max = 126
Bit rate
3000 kbit/s
1500 kbit/s
500 kbit/s
187.5 kbit/s
93.75 kbit/s
45.45 kbit/s
19.2 kbit/s
9.6 kbit/s