Starting up the device - RS 485 Modbus interface
Leuze electronic GmbH + Co. KG
CML 730i
157
Number of active beams
for area OFF
64
t16U
RW
0 … 1774 0
Specified middle of the
area
64
t16U
RW
0 … 1774 0
Specified width of the
area
64
t16U
RW
0 … 1774 0
Configuration of area 02
65
14 bytes info
area 02
RW
Configuration of area 02: definition of the status
conditions so that the area takes on a logical 1
or 0. For diagonal- or crossed-beam mode, the
numbers of the logical beams are to be entered.
Area
65
t08U
RW
0 … 1
0
0: Not active
1: Active
Active beam
65
t08U
RW
0 … 1
0
0: Light switching (beam is active if light path is
free)
1: Dark switching (beam is active if light path is
interrupted)
Start beam of area
65
t16U
RW
1 … 1774
65534
65533
65532
65531
1
Dynamic start positions are created by means of
entries in the form of impossible beam numbers.
65534: First interrupted beam (FIB)
65533: First not interrupted beam (FNIB)
65532: Last interrupted beam (LIB)
65531: Last not interrupted beam (LNIB)
End beam of area
65
t16U
RW
1 … 1774
65534
65533
65532
65531
1
Dynamic start positions are created by means of
entries in the form of impossible beam numbers.
65534: First interrupted beam (FIB)
65533: First not interrupted beam (FNIB)
65532: Last interrupted beam (LIB)
65531: Last not interrupted beam (LNIB)
Number of active beams
for area ON
65
t16U
RW
0 … 1774 0
Number of active beams
for area OFF
65
t16U
RW
0 … 1774 0
Specified middle of the
area
65
t16U
RW
0 … 1774 0
Specified width of the
area
65
t16U
RW
0 … 1774 0
....
....
....
....
....
....
....
....
....
....
....
....
....
....
Configuration of area 32
83
14 bytes info
area 32
RW
Configuration of area 32: definition of the status
conditions so that the area takes on a logical 1
or 0. For diagonal- or crossed-beam mode, the
numbers of the logical beams are to be entered.
Area
83
t08U
RW
0 … 1
0
0: Not active
1: Active
Active beam
83
t08U
RW
0 … 1
0
0: Light switching (beam is active if light path is
free)
1: Dark switching (beam is active if light path is
interrupted)
Start beam of area
83
t16U
RW
1 … 1774
65534
65533
65532
65531
1
Dynamic start positions are created by means of
entries in the form of impossible beam numbers.
65534: First interrupted beam (FIB)
65533: First not interrupted beam (FNIB)
65532: Last interrupted beam (LIB)
65531: Last not interrupted beam (LNIB)
End beam of area
83
t16U
RW
1 … 1774
65534
65533
65532
65531
1
Dynamic start positions are created by means of
entries in the form of impossible beam numbers.
65534: First interrupted beam (FIB)
65533: First not interrupted beam (FNIB)
65532: Last interrupted beam (LIB)
65531: Last not interrupted beam (LNIB)
Parameter
Index
(hex.)
Response
Data
type
Access Value
range
Default Explanation