Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
140
13.4.23 Autosplitting configuration (module 36)
Configuration of autosplitting (areas).
13.4.24 Area settings (modules 40 ... 71)
Configuration of the respective area: definition of the status conditions so that the area takes on a logical 1
or 0. For diagonal- or crossed-beam scanning, the numbers of the logical beams are to be entered.
• Module ID:1040 ... 1071
• Submodule ID: 1
Start beam of blanking area 1
2
USIGN 16
1 … 1774
1
End beam of blanking area 1
4
USIGN 16
1 … 1774
1
Log. value for blanking area 2
6.0 … 6.3
Bit field
0 … 4
0
0: No beams blanked
1: Blanked beams = log. 0
2: Blanked beams = log. 1
3: Value = lower-value adjacent beam
4: Value = higher-value adjacent beam
Start beam of blanking area 2
7
USIGN 16
1 … 1774
1
End beam of blanking area 2
9
USIGN 16
1 … 1774
1
Log. value for blanking area 3
11.0 … 11.3
Bit field
0 … 4
0
0: No beams blanked
1: Blanked beams = log. 0
2: Blanked beams = log. 1
3: Value = lower-value adjacent beam
4: Value = higher-value adjacent beam
Start beam of blanking area 3
12
USIGN 16
1 … 1774
1
End beam of blanking area 3
14
USIGN 16
1 … 1774
1
Log. value for blanking area 4
16.0 … 16.3
Bit field
0 … 4
0
0: No beams blanked
1: Blanked beams = log. 0
2: Blanked beams = log. 1
3: Value = lower-value adjacent beam
4: Value = higher-value adjacent beam
Start beam of blanking area 4
17
USIGN 16
1 … 1774
1
End beam of blanking area 4
19
USIGN 16
1 … 1774
1
Parameter data length: 21 bytes
Parameter
Rel. address.
Data type
Value range
Default
Explanation
Parameter
Rel.
address.
Data type
Value range
Default
Explanation
Logical behavior of the area
0.0
Bit
0 … 1
0
0: Logical OR linked
1: Logical AND linked
Number of areas
0.1 … 0.6
Bit field
1 … 32
1
Number of areas for autosplitting
Parameter data length: 1 byte
Parameter
Rel.
address.
Data type
Value range
Default Explanation
Area (active/not active)
0
Bit
0 … 1
0
0: Not active
1: Active
Logical behavior of the area
0.1
Bit
0 … 1
0
0: Active HIGH
1: Active LOW
Start beam mode
1.0 … 1.2 Bit field
0 … 5
1
0: Used beam number
1: Target minimum (FS)
2: Last not interrupted beam (LNIB)
3: Last interrupted beam (LIB)
4: First not interrupted beam (FNIB)
5: First interrupted beam (FIB)
Start beam of area
2
USIGN 16
1 … 1774
1
Valid beam in area 1 … 1774