Example configurations
Leuze electronic GmbH + Co. KG
CML 730i
183
Configuring light curtain 3:
Configure the trigger settings (triggered, slave, delay time (e.g., 25 ms = 25,000 µs)).
Configure the digital IOs (pin 5) settings.
Digital IOs (pin 5) settings
(group 10)
Parameter
0x51 Digital IO Pin 5 Settings
Write access:
01 10 00 51 00 02 04 00 01 00 01 A7 5F
Response to write access:
01 10 00 51 00 02 10 19
Cascading information
(group 7)
Parameter
0x49 cascading
Write access:
01 10 00 49 00 04 08 01 00 61 A8 64 00 01 00 1D 9C
Response to write access:
01 10 00 49 00 04 10 1C
Digital IOs (pin 5) settings
(group 10)
Parameter
0x51 Digital IO Pin 5 Settings
Write access:
01 10 00 51 00 02 04 00 01 00 01 A7 5F
Response to write access:
01 10 00 51 00 02 10 19
NOTICE
Halation effects can influence the measurement!