Example configurations
Leuze electronic GmbH + Co. KG
CML 730i
168
15.3.4 Configuration of hole recognition via PROFINET interface
For hole recognition for web material map hole indication to output pin 2.
15.3.5 Configuration of hole recognition via RS 485 Modbus interface
For hole recognition for web material map hole indication to output pin 2.
15.4 Example configuration - Activating and deactivating blanking areas
15.4.1 Configuration of blanking areas (general)
Perform the following settings to activate or deactivate blanking areas.
Example: automatic blanking of two areas during teaching
Example: Deactivation/resetting of auto blanking
Configuration of digital I/Os
(module 13)
Parameter
Pin 2 - Input/output selection
:
= 0
Pin 2 as output
Parameter
Pin 2 - Switching behavior
:
= 1
Switching behavior inverted
Parameter
Pin 2 - Output function
:
= 1
Switching output area 1 … 32
Parameter
Pin 2 - Area mapping 32 … 1
:
= 1
Bit mapping of area 01 to pin 2
Area settings
(module 40)
Parameter
Area configuration
:
= 1
Area 01 selected
Parameter
Area
:
= 1
Area 01 active
Parameter
Logical behavior of the area
:
= 0
0: Normal - light switching
Parameter
Start beam mode
:
= 5
First interrupted beam (FIB)
Parameter
End-beam mode
:
= 3
Last interrupted beam (LIB)
Parameter
Number of active beams → ON
:
= 1
Number of active beams for area ON
Parameter
Number of active beams → OFF
:
= 0
Number of active beams for area OFF
Configuration of digital I/Os
(module 32)
Parameter
Pin 2 - Input/output selection
:
= 0
Pin 2 as output
Parameter
Pin 2 - Switching behavior
:
= 1
Switching behavior inverted
Parameter
Pin 2 - Output function
:
= 1
Switching output area 1 … 32
Parameter
Pin 2 - Area mapping 32 … 1
:
= 1
Bit mapping of area 01 to pin 2
Area 01
(group 12)
Parameter
0x64 area 01
Write access (specified middle and specified width remain zero):
01 10 00 64 00 07 0E 01 00 FF FE FF FC 00 01 00 00 00 00 00
00 4E 48
Response to write access:
01 10 00 64 00 07 C0 14
Digital IO Pin 2 Settings
(group 10)
Parameter
0x50 Digital IO Pin 2 Settings
Write access:
01 10 00 50 00 02 04 00 00 01 F7 03
Response to write access:
01 10 00 50 00 02 41 D9
Configuration of switching output
pin 2
(group 11)
Parameter
0x54 configuration of switching
output pin 2
Write access:
01 10 00 54 00 04 08 00 00 00 00 00 00 01 FF C6 A5
Response to write access:
01 10 00 54 00 04 80 1A
Blanking settings
Parameter
Number of auto blanking areas
:
= 2
Two blanking areas permitted
Parameter
Auto blanking (during teaching)
:
= 1
Automatic blanking-area configuration active
System commands
Parameter
Teach command
:
= 1
Execute teach command