background image

EN

INSTRUCTION

EPRW

IN20027 REV. B, 2020-04-15

N

No

ottee!! More information about the product can be found in the manual,

which is available for download from www.regincontrols.com

C

Caauuttiioonn!! Read and understand the instruction before using the product.

C

Caauuttiioonn!! Ensure that the installation complies with local safety

regulations.

C

Caauuttiioonn!! Before installation or maintenance, the power supply should first

be disconnected. Installation or maintenance of this unit should only be
carried out by qualified personnel. The manufacturer is not responsible
for any eventual damage or injury caused by inadequate skills during instal-
lation, or through removal of or deactivation of any security devices.

Function

EPRW is a sensor that measures and monitors the output from an
electricity meter, using the electricity meter's built in LED. It reports the
power consumption (W) and the electric energy (kWh) to the receiver
RCW-M32.

The optical eye is placed on an electricity meter marked with a meter
constant in imp/kWh. The optical eye sensor counts the light pulses
from the meter, and sends a signal to the Modbus receiver. The energy
and power consumption can be followed up with a Modbus controller. If
the electricity meter uses a meter constant in kWh/imp, the reported
value from the EPRW must be recalculated.

Commissioning

The sensor must be paired with the receiver RCW-M32 before it can be
used.

For best performance, the optical eye is used in a room with no, or very
low, ambient light.

Technical Data

Supply voltage

Battery AA 1.5V L91 Lithium x 2

Battery life

6 years (calculated on activation every 5 minutes)

Frequency

868 MHz

Operating
temperature

-10...+50°C

Operating humidity

Max. 85 % RH

Protection class

IP30

Dimensions external
(WxHxD)

86 x 86 x 30 mm

Dimensions, optical
eye (WxHxD)

27 x 19 x 17 mm

Cable length

1 m

Installation

Installation of batteries

1. Open the cover by pressing the locking tab carefully with a

screwdriver.

2. Insert two 1.5 V L91 lithium batteries.

2

3

4

1

5

2

+

-

+

-

Number

Description

1

Battery compartments

2

Mounting holes

Number

Description

3

Test button

4

LED light

5

PCB connector for optical eye

Pairing the sensor with the receiver

Look in the receiver instruction (RCW-M32) for information on how to
pair the sensor with the receiver.

Pairing/connection test

The connection to the receiver must be tested before mounting the
sensor:

1. Place the receiver and the sensor at the desired locations.

2. Put the receiver into Programming mode (refer to the RCW-M32

instruction).

3. Perform a

Walk

test: Press the

Test button

on the sensor to see if the

sensor location is within signal range of the receiver. The LED light
will indicate if the sensor is paired with the receiver or not. There
will also be a long beep from the receiver when the sensor is paired
successfully.

LED indications

– 3 flashes (when

Test button

is pressed): The sensor is not paired with

the receiver.

– Flashing (when

Test button

is pressed): The sensor is paired with the

receiver.

– Flash every 4 seconds: Batteries need to be replaced.

Optical eye

The optical eye is magnetic and comes with a magnet for easy mounting
on the electricity meter.

Mounting the sensor

1. Use the mounting holes to mount the sensor on the wall.

2. Plug in the optical eye into the PCB connector. Use the punch outs

in the casing if necessary to have room for the cable.

3. Snap on the cover.

4. Centre the magnet for the optical eye as accurately as possible over

the LED light (imp/kWh) on the electrical meter.

5. Place the optical eye on the magnet over the LED light. The default

value is 1000 impulses/kWh (adjustable with Modbus tool).

Other functions

Pulse reading

EPRW

1

Содержание EPRW

Страница 1: ...tion class IP30 Dimensions external WxHxD 86 x 86 x 30 mm Dimensions optical eye WxHxD 27 x 19 x 17 mm Cable length 1 m Installation Installation of batteries 1 Open the cover by pressing the locking tab carefully with a screwdriver 2 Insert two 1 5 V L91 lithium batteries 2 3 4 1 5 2 Number Description 1 Battery compartments 2 Mounting holes Number Description 3 Test button 4 LED light 5 PCB conn...

Страница 2: ...nbyggda lysdiod Den rapporterar effektförbrukningen kW och elenergin kWh till mottagaren RCW M32 Det optiska ögat placeras på en elmätare som har en mätarkonstant angiven i imp kWh Det optiska ögat registrerar ljuspulser från elmätaren och skickar resultatet till Modbus mottagaren Energi och effektförbrukningen kan följas upp via en Modbus styrenhet Om elmätarens mätarkonstant är angiven i kWh imp...

Страница 3: ...nstallation oder Wartung muss zuerst die Stromversor gung unterbrochen werden Die Installation oder Wartung dieses Geräts darf nur von qualifizierten Fachkräften durchgeführt werden Der Herstel ler haftet nicht für eventuelle Schäden oder Verletzungen die durch man gelnde Fachkenntnisse bei der Installation oder durch das Entfernen oder Deaktivieren von Sicherheitsvorrichtungen entstehen Funktion ...

Страница 4: ...sor auf dem Magneten über der LED Leuchte Der Standardwert ist 1000 Impulse kWh einstellbar mit einem Modbus Tool Weitere Funktionen Impulserfassung Sobald der Sensor an den Stromzähler angeschlossen ist beginnt er mit der Erfassung der Impulse des Zählers Der Impulszählwert wird dem Empfänger in zwei getrennten Formaten gemeldet Der Detektor meldet die Anzahl der innerhalb eines festgelegten Inte...

Отзывы: