Starting up the device - CANopen interface
Leuze electronic GmbH + Co. KG
CML 730i
110
Parameter
Index
(hex.)
Sub-
index
Data
type
Access
Min.
value
Max. value Default Explanation
Device status
2162
t16S
RO
0: Normal function
1: Teach error
2: Internal temperature/volt
-
age monitoring
3: Invalid configuration
4: Hardware error
5: 24 V voltage error (supply
voltage U
B
)
6: Transmitter and receiver
incompatible
7: No connection to transmit
-
ter
8: Soiling
9: Teaching necessary
10: Measurement not active.
The device
• reconfigures itself
• (re)starts
• waits for the first trigger
pulse
• was manually stopped
11: Frequency of trigger sig
-
nal too high
R
X
error field
2600
t16U
RO
For internal diagnosis only
K
X
error field
2601
t16U
RO
For internal diagnosis only