Electrical connection
Leuze electronic GmbH + Co. KG
CML 730i
58
Table 7.5:
X1/X3 pin assignment – CML 700i with CANopen, PROFIBUS and RS 485 Modbus
interface
Connection cables: see table 21.7
Pin assignment on the short end of the Y-interconnection cable (PWR IN/digital IO)
5-pin, M12 connector (A-coded) on the short end of the Y-interconnection cable for connecting to PWR IN/
digital IO.
1
M12 connector (5-pin, A-coded)
Figure 7.11: X1 connection - PWR IN/digital IO
Table 7.6:
X1 pin assignment – PWR IN/digital IO
Connection cables: see table 21.8
Pin assignment on the long end of the Y-interconnection cable (PWR IN/digital IO)
The pin assignment on the long end of the Y-interconnection cable for synchronization of transmitter and
receiver for devices with fieldbus interface is the same as for IO-Link/analog (see chapter 7.5.3).
Pin (X1) X1 - Logic and power on the receiver and connection to transmitter
Pin (X3)
1
VIN: +24 V DC supply voltage
2
2
IO 1: input/output (configurable)
3
GND: ground (0 V)
3
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
6
RS 485 Tx-: synchronization
5
7
RS 485 Tx+: synchronization
4
8
SHD: FE functional earth, shield
1
1
PWR IN/Digital IO
Pin
X1 – Short end of the Y-interconnection cable
1
VIN: +24 V DC supply voltage
2
IO 1: input/output (configurable)
Ex works: teach input
3
GND: ground (0 V)
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
Ex works: trigger input