Starting up the device - PROFINET interface
Leuze electronic GmbH + Co. KG
CML 730i
127
The CML 700i corresponds to Conformance Class B (CC-B) and can use an existing Ethernet network
infrastructure.
The device supports the following features:
• Cyclical RT communication
• Acyclic TCP/IP communication
• Automatic address assignment
• I&M functionality 0 … 4
• Neighborhood detection basic functionality
• FAST Ethernet 100 Base-TX
• SNMP support
13.3 Configuration for control
The functionality of the CML 700i is defined via parameter sets which are organized in modules. The
modules are part of the GSDML file (Generic Station Description Markup Language), which is supplied as
an integral part of the device.
By using a control-specific software, such as, e.g. SIMATIC Manager for the Siemens PLC, the required
modules are integrated into a project during commissioning and its settings and parameters are configured
accordingly. These modules are provided by the GSDML file.
The following steps are necessary for commissioning:
• Preparation of the control, e.g. S7 PLC
• Installation of the GSDML file
• Hardware configuration of the control
• Transfer of the PROFINET configuration to the control, e.g. S7 PLC
• Device naming
• Check device name
Proceed as follows:
Prepare the control:
Assign an IP address to the control
Prepare the control system for consistent data transmission.
Install the GSDML file for the subsequent configuration of the CML 700i.
The GSDML file can be found at www.leuze.com.