85
CHAPTER 6. HYDRAULIC SYSTEM
2.4. RELIEF METAL (SUPPORT)
Relief pressure
5.4 Mpa (55 kgf/cm
2
)
at 10 liters/min.
and 50
°
C
Fig. 6-5
2.5. OIL FILTER (Return filter assembly)
The filter cartridge is attached on the HST unit.
Bypass relief valve in the base
Opening pressure
1.5 MPa (1.5 kgf/cm
2
)
Replace the cartridge with a new one after the
initial 50 hours of operation and then after every
200 hours of operaton.
From gear pump
From gear pump
3
4