Goodrive20-EU Series VFD
Function parameters
-73-
Function
code
Name
Description
Default Modify
13: Phase loss on input side (SPI)
14: Phase loss on output side (SPO)
15: Rectifier module overheat (OH1)
16: Inverter module overheat (OH2)
17: External fault (EF)
18: 485 communication fault (CE)
19: Current detection fault (ItE)
20: Motor autotuning fault (tE)
21: EEPROM operation fault (EEP)
22: PID feedback offline fault (PIDE)
23: Braking unit fault (bCE)
24: Running time reached (END)
25: Electronic overload (OL3)
26: Keypad communication error (PCE)
27: Parameter upload error (UPE)
28: Parameter download error (DNE)
29
–31: Reserved
32: To-ground short-circuit fault 1 (ETH1)
33: To-ground short-circuit fault 2 (ETH2)
34: Speed deviation fault (dEu)
35: Mal-adjustment (STo)
36: Underload fault (LL)
37: Safe torque off (STO)
38: Channel H1 abnormal (STL1)
39: Channel H2 abnormal (STL2)
40: Internal circuit abnormal (STL3)
41: Safety code FLASH CRC check fault (CrCE)
P07.33 Reference frequency of present fault
0.00Hz
●
P07.34 Ramps reference frequency of present fault
0.00Hz
●
P07.35 Output voltage of present fault
0V
●
P07.36 Output current of present fault
0.0A
●
P07.37 Bus voltage of present fault
0.0V
●
P07.38 Max. temperature of present fault
0.0°C
●
P07.39 Input terminals state of present fault
0
●
P07.40 Output terminals state of present fault
0
●
P07.41 Running frequency of the last fault
0.00Hz
●
P07.42 Ramps reference frequency of the last fault
0.00Hz
●
P07.43 Output voltage of the last fault
0V
●
Содержание Goodrive20-EU VFD Series
Страница 1: ......