Goodrive20-EU Series VFD
Fault tracking
-110-
Fault
code
Fault type
Possible cause
Solutions
PIDE
[22] PID
feedback offline
fault
PID feedback offline;
PID feedback source
disappear.
Check the PID feedback
signal wire;
Check the PID feedback
source.
bCE
[23] Braking unit
fault
Braking circuit fault or
damage to the brake
pipes;
The external braking
resistor is not sufficient.
Check the braking unit and
change to new brake pipe;
Increase the braking
resistor.
END
[24] Running
time reached
The actual running time of
the VFD is larger than the
internal setting running
time.
Ask for the supplier and
adjust the setting running
time.
OL3
[25] Electronic
overload
The VFD will report
overload pre-alarm
according to the set value.
Check the load and the
overload pre-alarm point.
PCE
[26] Keypad
communication
error
The keypad is not in good
connection or offline;
The keypad cable is too
long and there is strong
interference;
Part of the communication
circuits of the keypad or
main board have fault.
Check the keypad cable
and ensure it is normal;
Check the environment
and eliminate the
interference source;
Change hardware and ask
for maintenance service.
UPE
[27] Parameter
upload error
The keypad is not in good
connection or offline;
The keypad cable is too
long and there is strong
interference;
Part of the communication
circuits of the keypad or
main board have fault.
Check the environment
and eliminate the
interference source;
Replace the hardware and
ask for maintenance
service;
Change hardware and ask
for maintenance service.
DNE
[28] Parameter
download error
The keypad is not in good
connection or offline;
The keypad cable is too
long and there is strong
interference;
Data storage error in
Check the environment
and eliminate the
interference source;
Replace the hardware and
ask for maintenance
service;
Содержание Goodrive20-EU VFD Series