Goodrive20-EU Series VFD
Function parameters
-90-
Function
code
Name
Description
Default Modify
P10.33
Running time
of step 15
Setting
range
of
P10.(2n+1,
1<n<17):
0.0
–6553.5s (min)
0.0s
○
P10.34
Acceleration/
deceleration
time selection
of simple PLC
0
–7 step
Below is the detailed instruction:
Function
code
Binary bit
Step
ACC/
DEC 0
ACC/
DEC 1
ACC/
DEC 2
ACC/
DEC 3
P10.34
BIT1
BIT0
0
00
01
10
11
BIT3
BIT2
1
00
01
10
11
BIT5
BIT4
2
00
01
10
11
BIT7
BIT6
3
00
01
10
11
BIT9
BIT8
4
00
01
10
11
BIT11 BIT10
5
00
01
10
11
BIT13 BIT12
6
00
01
10
11
BIT15 BIT14
7
00
01
10
11
P10.35
BIT1
BIT0
8
00
01
10
11
BIT3
BIT2
9
00
01
10
11
BIT5
BIT4
10
00
01
10
11
BIT7
BIT6
11
00
01
10
11
BIT9
BIT8
12
00
01
10
11
BIT11 BIT10
13
00
01
10
11
BIT13 BIT12
14
00
01
10
11
BIT15 BIT14
15
00
01
10
11
After the users select the corresponding
ACC/DEC time, the combining 16 binary bit will
change into decimal bit, and then set the
corresponding function codes.
Setting range: -0x0000
–0xFFFF
0x0000
○
P10.35
Acceleration/
deceleration
time selection
of simple PLC
8
–15 step
0x0000
○
P10.36
PLC restart
mode
0: Restart from the first stage; stop during
running (caused by the stop command, fault or
power loss), run from the first stage after restart.
1: Continue to run from the stop frequency; stop
during running (cause by stop command and
fault), the VFD will record the running time
automatically, enter into the stage after restart
and keep the remaining running at the setting
frequency.
0
◎
P10.37
Multi-step time
unit selection
0: Seconds; the running time of all stages is
counted by second
0
◎