Goodrive20-EU Series VFD
Function parameters
-36-
Function
code
Name
Description
Default Modify
100.0% of the high speed pulse input setting
corresponds to the maximum frequency in
forward direction (function code P00.03) and
-100.0% corresponds to the maximum frequency
in reverse direction (function code P00.03).
Note:
The pulse setting can only be input by
multi-function terminals HDI. Set P05.00 (HDI
input selection) to high speed pulse input.
5: Set via simple PLC program
The VFD runs at simple PLC program mode
when P00.06=5 or P00.07=5. Set P10 (simple
PLC and multi-step speed control) to select the
running frequency running direction, ACC/DEC
time and the keeping time of corresponding
stage. See the function description of P10 for
detailed information.
6: Set via multi-step speed running
The VFD runs at multi-step speed mode when
P00.06=6 or P00.07=6. Set P05 to select the
current running step, and set P10 to select the
current running frequency.
The multi-step speed has the priority when
P00.06 or P00.07 does not equal to 6, but the
setting stage can only be the 1
–15 stage. The
setting stage is 1
–15 if P00.06 or P00.07 equals
to 6.
7: Set via PID control
The running mode of the VFD is process PID
control when P00.06=7 or P00.07=7. It is
necessary to set P09. The running frequency of
the VFD is the value after PID effect. See P09 for
the detailed information of the preset source,
preset value and feedback source of PID.
8: Set via Modbus communication
The frequency is set by Modbus communication.
See P14 for detailed information.
9
–11: Reserved