Goodrive20-EU Series VFD
Function parameters
-80-
Function
code
Name
Description
Default Modify
than 10% of the VFD rated current. If the VFD
ramp frequency is 0 Hz and the VFD output
current is less than 10% of the VFD rated current
or the VFD stops running, the fan stops running
within 1 minute.
P08.40 PWM selection
0x000
–0x0021
Ones place: PWM mode selection
0: PWM mode 1, three-phase modulation and
two-phase modulation
1: PWM mode 2, three-phase modulation
Tens place: low-speed carrier frequency limit
mode
0: Low-speed carrier frequency limit mode 1, the
carrier frequency will limit to 1k or 2k if it exceeds
2k at low speed
1: Low-speed carrier frequency limit mode 2, the
carrier frequency will limit to 4k if it exceeds 4k at
low speed
2: No limit
0x01
◎
P08.41
Overmodulation
selection
Ones place:
0: Disabled
1: Enabled
Tens place:
0: Light overmodulation; restricted in zone 1
1: Heavy overmodulation; restricted in zone 2
For
VFDs of 1PH 220V/3PH 380V (≤2.2kW) and
3PH 220V (≤0.75kW), the default value is 00;
for those
of 3PH 380V (≥4kW) and 3PH 220V
(≥1.5kW), the default value is 01.
0x00
◎
0x01
P08.42
Keypad digital
control setting
0x0000
–0x1223
Ones place: frequency enable selection
0: Both
∧
/
∨
keys and analog potentiometer
adjustments are valid
1: Only
∧
/
∨
keys adjustment is valid
2: Only analog potentiometer adjustments is
valid
3: Neither
∧
/
∨
keys nor digital potentiometer
adjustments are valid
0x0000
○