![INVT GD300-004G-4 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/invt/gd300-004g-4/gd300-004g-4_operation-manual_2085739073.webp)
Goodrive300
inverters Function codes
72
Functi
on
code
Name
Detailed instruction of parameters
Default
value
Modif
y
P03.22
Weakening
coefficient
in constant
power zone
0.3
○
P03.23
Lowest
weakening
point in
constant
power zone
The usage of motor in weakening control.
Function code P03.22 and P03.23 are effective at
constant power. The motor will enter into the
weakening state when the motor runs at rated
speed. Change the weakening curve by modifying
the weakening control coefficienct. The bigger the
weakening control coefficienct is, the steeper the
weak curve is.
The setting range of P03.22:0.1~2.0
The setting range of P03.23:10%~100%
20%
○
P03.24
Max.
voltage limit
P03.24 set the Max. Voltage of the inverter, which
is dependent on the site situation.
The setting range:0.0~120.0%
100.0%
◎
P03.25
Pre-excitin
g time
Preactivate the motor when the inverter starts up.
Build up a magnetic field inside the inverter to
improve the torque performance during the starting
process.
The setting time:0.000~10.000s
0.300s
○
P03.26
Weak
magnetic
proportiona
l gain
0~8000
Note: P03.24~P03.26 are invalid for vector mode.
1000
○
P03.27
Vector
0: Display the actual value
1: Display the setting value
0
○
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...