Goodrive300
inverters Function codes
52
Functi
on
code
Name
Detailed instruction of parameters
Default
value
Modif
y
source
command
2: A+B, the current frequency setting is A frequency
c B frequency command
3: A-B, the current frequency setting is A frequency
command - B frequency command
4: Max (A, B):The bigger one between A frequency
command and B frequency is the set frequency.
5: Min (A, B):The lower one between A frequency
command and B frequency is the set frequency.
Note:The combination manner can be shifted by
P5(terminal function)
P00.10
Keypad set
frequency
When A and B frequency commands are selected
as “keypad setting”, the value of the function code
is the original setting one of the frequency data of
the inverter.
Setting range:0.00 Hz~P00.03(the Max. frequency)
50.00H
z
○
P00.11 ACC time 1
Depend
on
model
○
P00.12 DEC time 1
ACC time means the time needed if the inverter
speeds up from 0Hz to the Max. One (P00.03).
DEC time means the time needed if the inverter
speeds down from the Max. Output frequency to
0Hz (P00.03).
Goodrive300 series inverters define four groups of
ACC/DEC time which can be selected by P05. The
factory default ACC/DEC time of the inverter is the
first group.
Setting range of P00.11 and P00.12:0.0~3600.0s
Depend
on
model
○
P00.13
Running
direction
0: Runs at the default direction, the inverter runs in
the forward direction. FWD/REV indicator is off.
1:Runs at the reverse direction, the inverter runs in
the reverse direction. FWD/REV indicator is on.
Modify the function code to shift the rotation
direction of the motor. This effect equals to the
0
○
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...