Goodrive300
inverters Basic operation instruction
174
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P00.01
Run command channel
0:Keypad running command
1:Terminal running command channel
(“LOCAL/REMOT” flickering)
2:Communication
running
command
channel (“LOCAL/REMOT” on);
1
P00.11
ACC time 1
0.0~3600.0s
Depend
on model
P00.12
DEC time 1
0.0~3600.0s
Depend
on model
P01.00
Start mode
0:Start-up directly
1:Start-up after DC braking
2: Start-up after rotation speed tracking 1
0
P01.01
Starting frequency of
direct start
0.00~50.00Hz
0.50Hz
P01.02
Retention time of the
starting frequency
0.0~50.0s
0.0s
P01.03
The braking current before
starting
0.0~150.0%
0.0%
P01.04
The braking time before
starting
0.0~50.0s
0.0s
P01.05
ACC/DEC selection
0:Linear type
1: Reserved
0
P01.06
Reserved
P01.07
Reserved
P01.08
Stop mode
0:Decelerate to stop
1:Coast to stop
0
P01.09
Starting frequency of DC
braking
0.00Hz~P00.03(the Max. frequency)
0.00Hz
P01.10
Waiting time of DC
braking
0.0~50.0s
0.0s
P01.11
DC braking current
0.0~150.0%
0.0%
P01.12
DC braking time
0.0~50.0s
0.0s
P01.13
Dead time of FWD/REV
0.0~3600.0s
0.0s
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...