Goodrive300
inverters Basic operation instruction
169
Function
code
Name
Detailed instruction of parameters
Default
value
asynchronous motor 1
on model
P02.08
Leakage inductance of
asynchronous motor 1
0.1~6553.5mH
Depend
on model
P02.09
Mutual inductance of
asynchronous motor 1
0.1~6553.5mH
Depend
on model
P02.10
Non-load current of
asynchronous motor 1
0.1~6553.5A
Depend
on model
P02.15
Rated power of
synchronous motor 1
0.1~3000.0kW
Depend
on model
P02.16
Rated frequency of
synchronous motor 1
0.01Hz~P00.03(the Max. frequency)
50.00Hz
P02.17
Number of poles pairs for
synchronous motor 1
1~50
2
P02.18
Rated voltage of
synchronous motor 1
0~1200V
Depend
on model
P02.19
Rated current of
synchronous motor 1
0.8~6000.0A
Depend
on model
P02.20
Stator resistor of
synchronous motor 1
0.001~65.535Ω
Depend
on model
P02.21
Direct axis inductance of
synchronous motor 1
0.1~6553.5mH
Depend
on model
P02.22
Quadrature axis
inductance of
synchronous motor 1
0.1~6553.5mH
Depend
on model
P02.23
Back EMF constant of
synchronous motor 1
0~10000
300
P05.01~P0
5.09
Multi-function digital input
terminals
(S1~S8, HDI) function
selection
35: Shift from motor 1 to motor 2
P08.31
Motor shifting
LED ones: shifting channel
0: terminal shifting; digital terminal is 35
1: MODBUS communication shifting
2: PROFIBUS communication shifting
0
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...