Goodrive300
inverters Basic operation instruction
213
Function
code
Name
Detailed instruction of parameters
Default
value
P08.26
Reference counting value 0~P08.25
0
P17.18
Counting value
0~65535
0
7.18 Fixed-length control
Goodrive300 series inverters support fixed-length control function which can input length counting
pulse through HDI, and then count the actual length according to the internal counting formula. If
the actual length is longer than or equal to the set length, the digital output terminal can output the
length arrival pulse signal of 200ms and the corresponding length will clear automatically.