![INVT GD300-004G-4 Скачать руководство пользователя страница 251](http://html1.mh-extra.com/html/invt/gd300-004g-4/gd300-004g-4_operation-manual_2085739251.webp)
Goodrive300
inverters Communication protocol
250
Function
instruction
Address
definition
Data meaning instruction
R/W
characteristics
separation)
(0~1000, 1000 corresponds to the 100.0%)
200DH
AO output setting 1
(-1000~1000, 1000 corresponds to 100.0%)
W/R
200EH
AO output setting 2
(-1000~1000, 1000 corresponds to 100.0%)
W/R
0001H:forward running
0002H:forward running
0003H:stop
0004H:fault
0005H: POFF state
SW 1 of the
inverter
2100H
0006H: pre-exciting state
R
SW 2 of the
inverter
2101H
Bit0: =0:ready for operation =1:not ready for
operation
Bi1~2:=00:motor 1 =01:motor 2
=10:motor 3 =11:motor 4
Bit3: =0:asynchronous motor
=1:synchronous motor
Bit4:=0:pre-alarm without overload
=1:overload pre-alarm
Bit5~ Bit6: =00: keypad control =01: terminal
contorl
=10: communication control
R
Fault code of the
inverter
2102H
See the fault type instruction
R
Identifying code
of the inverter
2103H
Goodrive300-----0x0110
R
Operation
frequency
3000H
0~Fmax (unit: 0.01Hz)
R
Setting freqency
3001H
0~Fmax (unit: 0.01Hz)
R
Bus voltage
3002H
0.0~2000.0V (unit: 0.1V)
R
Output voltage
3003H
0~1200V (unit: 1V)
R
Output current
3004H
0.0~3000.0A (unit: 0.1A)
R
Rotation speed
3005H
0~65535 (unit: 1RPM)
R
Output power
3006H
-300.0~300.0% (unit: 0.1%)
R
Output torque
3007H
-250.0~250.0% (unit: 0.1%)
R
Close loop
3008H
-100.0~100.0% (unit: 0.1%)
R
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...