Goodrive300
inverters Function codes
46
Function Parameters 6
6.1 What this chapter contains
This chapter lists and describes the function parameters.
6.2 Goodrive300 general series function parameters
The function parameters of Goodrive300 series inverters have been divided into 30 groups
(P00~P29) according to the function, of which P18~P28 are reserved. Each function group
contains certain function codes applying 3-level menus. For example, “P08.08” means the
eighth function code in the P8 group function, P29 group is factory reserved, and users are
forbidden to access these parameters.
For the convenience of function codes setting, the function group number corresponds to the
first level menu, the function code corresponds to the second level menu and the function
code corresponds to the third level menu.
1.
Below is the instruction of the function lists:
The first line
“Function code”: codes of function parameter group and parameters
;
The second line
“Name”: full name of function parameters
;
The third line
“Detailed illustration of parameters”: detailed illustration of the function
parameters
The fourth line
“Default value”: the original factory values of the function parameter
;
The fifth line
“Modify”: the modifying character of function codes (the parameters can be
modified or not and the modifying conditions), below is the instruction:
“
○
”: means the set value of the parameter can be modified on stop and running state
;
“
◎
”: means the set value of the parameter can not be modified on the running state
;
“
●
”: means the value of the parameter is the real detection value which can not be
modified.
(The inverter has limited the automatic inspection of the modifying character of the
parameters to help users avoid mismodifying)
2.
“Parameter radix” is decimal (DEC), if the parameter is expressed by hex, then the
parameter is separated from each other when editing. The setting range of certain bits are
0~F (hex).
3.
”The default value” means the function parameter will restore to the default value during
default parameters restoring. But the detected parameter or recorded value won’t be
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...