Goodrive300
inverters Basic operation instruction
209
Function
code
Name
Detailed instruction of parameters
Default
value
6:Ethernet communication feedback
7:Reserve
P09.03
PID output feature
0:PID output is positive
1:PID output is negative
0
P09.04
Proportional gain (Kp)
0.00~100.00
1.00
P09.05
Intergal time(Ti)
0.00~10.00s
0.10s
P09.06
Differential time(Td)
0.00~10.00s
0.00s
P09.07
Sampling cycle(T)
0.00~100.00s
0.10s
P09.08
PID control deviation limit 0.0~100.0%
0.0%
P09.09
Output upper limit of PID
P09.10~100.0%
(Max. frequency or the Max. voltage)
100.0%
P09.10
Output lower limit of PID
-100.0%~P09.09
(Max. frequency or the Max. voltage)
0.0%
P09.11
Detection value of
feedback offline
0.0~100.0%
0.0%
P09.12
Detection time of
feedback offline
0.0~3600.0s
1.0s
P09.13
PID adjustment
0x00~0x11
LED ones:
0:Keep the integral adjustment ON while
the frequency achieves upper or lower
limit.
1:Stop the integral adjustment while the
frequency achieves the upper or lower
limit
LED tens:
0:The same with the setting direction
1:Opposite to the setting direction
0x00
P17.00
Set frequency
0.00Hz~P00.03 (the Max. frequency)
0.00Hz
P17.23
PID reference
-100.0~100.0%
0.0%
P17.24
PID feedback
-100.0~100.0%
0.0%
7.16 Traverse running
Traverse is applied in some industries such as textile, chemical fiber and cases where traverse and
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...