![INVT GD300-004G-4 Скачать руководство пользователя страница 149](http://html1.mh-extra.com/html/invt/gd300-004g-4/gd300-004g-4_operation-manual_2085739149.webp)
Goodrive300
inverters Basic operation instruction
148
Note:
If fault occurs, please do as the
“
Fault Tracking
”
. Esitimate the fault reason and settle the
issue.
Besides P00.01 and P00.02, terminal command setting can also used to set the running command
channel.
Current runnig
command channel
P00.01
Multi-function terminal
36
Switch to keypad
Multi-function
terminal 37
Switch to to terminal
Multi-function terminal
38
Switch to to
communication
Keypad runnig
command channel
/
Terminal runnig
command channel
Communication
runnig command
channel
Terminal runnig
command channel
Keypad runnig
command channel
/
Communication
runnig command
channel
Communication
runnig command
channel
Keypad runnig
command channel
Terminal runnig
command channel
/
Note:
“
/
”
means the multi-function terminal is invalid on the current given channel.
Relative parameters table:
Function
code
Name
Detailed instruction of parameters
Default
value
P00.00
Speed control mode
0: Sensorless vector control mode 0
(apply to AM and SM)
1: Sensorless vector control mode 1
(applying to AM)
2:V/F control
1
P00.01
Run command channel
0:Keypad running command
1:Terminal running command channel
(“LOCAL/REMOT” flickering)
2:Communication running command
channel (“LOCAL/REMOT” on);
0
P00.02
Communication running
commands
0:MODBUS communication channel
1:
PROFIBUS\CANopen communication
channel
0
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...