Insert the module into the defined location carefully and fix it on the copper column
with screw.
●
Set the bus terminal switch of the module to the needed location.
3. Notes:
Disconnect the device from the power line before installation. Wait for at least three minutes
to let the capacitors discharge. Cut off dangerous voltage from external control circuit to the
unit output and input terminals.
Some electric components are sensitive to static charge. Do not touch the circuit board. If
you have to operate on it, please wear the grounding wrist belt.
A.2.6.2 Electrical installation of EC-TX-103 communication card
1. Node selection
Node address is the only address of PROFIBUS on the bus. The address which is among
00~99 is shown with two figures and is selected by the spinning switch on the module. The
left switch shows the first number and the right one show the second number.
Node address = 10 x the first digital value + the second digital value x 1
2. Bus terminals
There is a bus terminal in each heading and ending to avoid error during operation. The DIP
switch on RPBA-01PCB is used to connect the bus terminals which can avoid the signal
feedback from the bus cables. If the module is the first or last one in the internet, the bus
terminal should be set as ON. Please disconnect EC-TX-103 communication card terminals
when the PROFIBUS D-sub connector with internal terminals is in use.
A.2.6.3 Bus net connection of EC-TX-103 communication card
Bus communication interface
Transformation by double-shielded twisted pair copper cable is the most common way in
PROFIBUS (conform to RS-485standard).
The basic characteristics of transformation technology:
●
Net topology:Linear bus, there are bus resistor in two ends.
●
Transforming speed:
9.6k bit/s~12M bit/s
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...