191
Set
value
Function
Instructions
22
ACC/DEC time selection 2
terminals.
Terminal
1
Terminal
2
ACC/DEC time
selection
Corresponding
parameter
OFF
OFF
ACC/DEC time 1 P00.11/P00.12
ON
OFF
ACC/DEC time 2 P08.00/P08.01
OFF
ON
ACC/DEC time 3 P08.02/P08.03
ON
ON
ACC/DEC time 4 P08.04/P08.05
23
Simple PLC stop reset
Restart simple PLC and clear the memory state of
PLC.
24
Simple PLC pause
Program pause during PLC implement. Run at the
current speed stage. After cancel the function, simple
PLC continues to run.
25
PID control pause
Temporal PID invalid and the inverter will output at the
current frequency.
26
Traverse pause (stop at the
current frequency)
The inverter will stop at the current output and after
canceling the function, the inverter will continue to
traverse run at the current frequency.
27
Traverse reset (return to the
middle frequency)
The setting frequency of the inverter will come back to
the middle frequency.
28
Counter reset
Counter clear
29
Torque control disabling
The inverter shifts from torque control mode to speed
control mode.
30
ACC/DEC disabling
Ensure the inverter will not be affected by the external
signals (except for the stopping command) and keep
the current output frequency.
31
Counter trigging
Enable the pulse counter.
32
Length reset
Length counter clear
33
Frequency
increasing/decreasing setting
temporal clear
When the terminal closes, the frequency set by
UP/DOWN can be cleared. All set frequency will be
restored into the given frequency by the frequency
command channel and the frequency will come back
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...