Goodrive300
inverters Appendix A
274
Response
PKW1 PKW2 PKW3 PKW4
CW
PZD2
PZD3
PZD12
00 01 00 04 00 00 50
xx
···
···
xx xx xx xx xx
xx xx
0001: Reponse (Parameter values refreshed)
00
5000: Address 4 parameter
Example 2:
Modify the parameter values (RAM and EEPROM are modified)
Modify keypad settings frequency value (the address of keypad set frequency is 4) which
can be achieved by setting PKW1 as 2; PKW2 as 4, modification value (50.00) is in PKW4.
Request (From master to inverter):
Requst
PKW1 PKW2 PKW3 PKW4
CW
PZD2
PZD3
PZD12
00 02 00 04 00 00 50
xx
···
···
xx xx xx xx xx
xx xx
0004: Parameter changes
00
5000: Address 4 parameter
Response (From inverter to master)
Response
PKW1 PKW2 PKW3 PKW4
CW
PZD2
PZD3
PZD12
00 01 00 04 00 00 50
xx
···
···
xx xx xx xx xx
xx xx
0001: Response (Parameter values refreshed)
00
Example for PZD:
Transmission of PZD area is achieved through inverter function code; please refer to
relevant INVT inverter user manual to know relevant function code.
Example 1:
Read process data of inverter
Inverter parameter selects "8: Run frequency" as PZD3 to transmit which can be achieved
by setting Pd.14 as 8. This operation is mandatory until the parameter is instead of others.
Request (From master to inverter):
PKW1 PKW2 PKW3
PKW4
CW
PZD2
PZD3
…
PZD12
Response xx xx xx xx xx xx xx
xx xx
xx xx
xx 00
0A … xx
xx
Example 2:
Write process data into inverter
Inverter parameter selects "2”: Traction given" from PZD3 which can be achieved by setting
Pd.03 as 2. In each request frame, parameters will use PZD3 to update until re-select a
parameter.
Request (From master to converter):
PKW1 PKW2 PKW3 PKW4
CW
PZD2
PZD3
…
PZD12
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...