Goodrive300
inverters Basic operation instruction
204
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P10.02
Multi-step speed 0
-100.0~100.0%
0.0%
P10.03
The running time of step 0 0.0~6553.5s(min)
0.0s
P10.04
Multi-step speed 1
-100.0~100.0%
0.0%
P10.05
The running time of step 1 0.0~6553.5s(min)
0.0s
P10.06
Multi-step speed 2
-100.0~100.0%
0.0%
P10.07
The running time of step 2 0.0~6553.5s(min)
0.0s
P10.08
Multi-step speed 3
-100.0~100.0%
0.0%
P10.09
The running time of step 3 0.0~6553.5s(min)
0.0s
P10.10
Multi-step speed 4
-100.0~100.0%
0.0%
P10.11
The running time of step 4
0.0~6553.5s(min)
0.0s
P10.12
Multi-step speed 5
-100.0~100.0%
0.0%
P10.13
The running time of step 5 0.0~6553.5s(min)
0.0s
P10.14
Multi-step speed 6
-100.0~100.0%
0.0%
P10.15
The running time of step 6 0.0~6553.5s(min)
0.0s
P10.16
Multi-step speed 7
-100.0~100.0%
0.0%
P10.17
The running time of step 7 0.0~6553.5s(min)
0.0s
P10.18
Multi-step speed 8
-100.0~100.0%
0.0%
P10.19
The running time of step 8 0.0~6553.5s(min)
0.0s
P10.20
Multi-step speed 9
-100.0~100.0%
0.0%
P10.21
The running time of step 9 0.0~6553.5s(min)
0.0s
P10.22
Multi-step speed 10
-100.0~100.0%
0.0%
P10.23
The running time of step 10 0.0~6553.5s(min)
0.0s
P10.24
Multi-step speed 11
-100.0~100.0%
0.0%
P10.25
The running time of step 11 0.0~6553.5s(min)
0.0s
P10.26
Multi-step speed 12
-100.0~100.0%
0.0%
P10.27
The running time of step 12 0.0~6553.5s(min)
0.0s
P10.28
Multi-step speed 13
-100.0~100.0%
0.0%
P10.29
The running time of step 13 0.0~6553.5s(min)
0.0s
P10.30
Multi-step speed 14
-100.0~100.0%
0.0%
P10.31
The running time of step 14 0.0~6553.5s(min)
0.0s
P10.32
Multi-step speed 15
-100.0~100.0%
0.0%
P10.33
The running time of step 15 0.0~6553.5s(min)
0.0s
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...