Function
code
Name
Detailed instruction of parameters
Default
value
1:UP/DOWN terminals setting valid
LED tens: frequency control selection
0:Only valid when P00.06=0 or P00.07=0
1:All frequency means are valid
2:When the multi-step are priority, it is
invalid to the multi-step
LED hundreds: action selection when
stop
0:Setting valid
1: Valid in the running, clear after stop
2: Valid in the running, clear after
receiving the stop commands
P08.45
UP terminals frequency
changing ratio
0.01~50.00Hz/s
0.50 Hz/s
P08.46
DOWN terminals
frequency changing ratio
0.01~50.00 Hz/s
0.50 Hz/s
P17.00
Setting frequency
Display current set frequency of the
inverter
Range: 0.00Hz~P00.03
0.00Hz
P17.02
Ramp reference frequency
Display current ramp given frequency of
the inverter
Range: 0.00Hz~P00.03
0.00Hz
P17.14
Digital adjustment
Display the adjustment through the
keypad of the inverter.
Range : 0.00Hz~P00.03
0.00V
7.9 Analog input
Goodrive300 series inverters have three analog input terminals and 1 high-speed pulse input
terminals (of which, AI1 and AI2 are 0~10V/0~20mA and Al can select voltage input or current input
by J1, A2 can select voltage input or current input by J2 and AI3 is for -10~10V ) as the standard
configuration. The inputs can be filtered and the maximum and minimum values can be adjusted.
Содержание GD300-004G-4
Страница 1: ...3...
Страница 148: ...Goodrive300 inverters Basic operation instruction 147...
Страница 159: ...Goodrive300 inverters Basic operation instruction 158...
Страница 164: ...Goodrive300 inverters Basic operation instruction 163...
Страница 173: ...Goodrive300 inverters Basic operation instruction 172...
Страница 189: ...Goodrive300 inverters Basic operation instruction 188...
Страница 204: ...Goodrive300 inverters Basic operation instruction 203...
Страница 211: ...Goodrive300 inverters Basic operation instruction 210 convolution is required The working flowchart is as below...
Страница 227: ...Goodrive300 inverters Fault tracking 226 8 6 2 Motor vibration...
Страница 228: ...Goodrive300 inverters Fault tracking 227 8 6 3 Overvoltage 8 6 4 Undervoltage fault...
Страница 312: ...1 1 0 0 1 0 0 7 7 9 C E 66001 00035 201303 V1 4...