Section V. Parameter Function Table
58
When analog input voltage exceeds the setup “maximum input” limit, analog voltage is calculated as
“maximum input” .Similarly, when analog input is smaller than the setup “minimum input”,analog voltage is
calculated as minimum input or 0.0% according to the setting of F4.34.
AI used as current input terminal
:
1mA current equals to 0.5V voltage.
AI input filtering time is used to set AI1 software filtering time.When field anlog quantity is vulnerable,
please increase the filtering time so that analog quantity tends to be stable. But excessive filtering time will
lead to slow response time to analog detection. User should balance it according to practical application
cases.
In various application cases, the nominal value corresponding to 100% of analog reference will be
different. Refer to specific application description for the specific value.
Figure 5.10 shows typical setup cases.
F4.18
AI curve 2 minimum input
0.00V~F4.20
0.00V
☆
F4.19
AI curve 2 minimum input
corresponding setup
-100.00%~100.0%
0.0%
☆
F4.20
AI curve 2 maximum input
F4.18~10.00V
10.00V
☆
F4.21
AI curve 2 maximum input
corresponding setup
-100.00%~100.0%
100.0%
☆
F4.22
AI2 filter time
0.00s~10.00s
0.10s
☆
For function and usage of curve 2, please refer to description of curve 1.
F4.23
AI curve 3 minimum input
-10.00V~F4.25
-10V
☆
F4.24
AI curve 3 minimum input
corresponding setup
-100.00%~100.0%
0.0%
☆
F4.25
AI curve3 maximum input
F4.23~10.00V
8.60V
☆
F4.26
AI curve 3 maximum input
corresponding setup
-100.00%~100.0%
100.0%
☆
F4.27
AI3filter time
0.00s~10.00s
0.10s
☆
For function and usage of curve 3, please refer to description of curve 1.
F4.28
PULSE minimum input
0.00kHz~F4.30
0.00kHz
☆
F4.29
PULSE minimum input
corresponding setup
-100.00%~100.0%
0.0%
☆
F4.30
PULSE maximum input
F4.28~50.00kHz
50.00kHz
☆
F4.31
PULSE maximum input
corresponding setup
-100.00%~100.0%
100.0%
☆
F4.32
PULSE filter time
0.00s~10.00s
0.10s
☆
This group of parameters are used to set relationship between X5 pulse frequency and it’s
corresponding settings.
Pulse frequency can be only input to the inverter through X5 channel. This function group’s
applications are similar to curve 1,please refer to the description of curve 1.