Section V. Parameter Function Table
110
A2.39 Speed loop integration time1
0.01s~10.00s
0.50s
☆
A2.40 Switching frequency1
0.00~A2.43
5.00Hz
☆
A2.41 Speed loop proportional gain 2 0~100
20
☆
A2.42 Speed loop integration time 2
0.01s~10.00s
1.00s
☆
A2.43
Switching frequency 2
A2.40~maximum output frequency
10.00Hz
☆
A2.44
Vector control slip gain
50%~200%
150%
☆
A2.45
Speed-loop filtering time
0.000s~0.100s
0.000s
☆
A2.47
Torque upper limit source in
speed control mode
A2.48 setup
0
0
☆
AI1
1
AI2
2
AI3
3
PULSE setup
4
Communication setup
5
MIN(AI1,AI2)
6
MAX(AI1,AI2)
7
A2.48
Torque upper limit digital
setup in speed control
mode
0.0%~200.0%
150.0%
☆
A2.51
Excitation regulation
proportional gain
0~60000
2000
☆
A2.52
Excitation regulation
integration gain
0~60000
1300
☆
A2.53
Torque requlation
proportional gain
0~60000
2000
☆
A2.54
Torque regulation
integration gain
0~60000
1300
☆
A2.55
Speed loop integration
attribute
1bit
Integration separation
0
☆
Invalid
0
Valid
1
A2.61
Motor2 control mode
Speed sensorless vector control(SVC)
0
0
★
Speed sensor vector control(FVC)
1
V/F control
2
A2.62
Motor 2 acc./dec. time
selection
Same with the first motor
0
0
☆
Acceleration time1
1
Acceleration time 2
2
Acceleration time 3
3
Содержание HV610C Series
Страница 1: ...HV610C Series Frequency Inverter User Manual HNC Electric Limited ...
Страница 25: ...Section II Installation Wiring 12 2 3 2 Typical wiring of HV610C in Crane applications ...
Страница 29: ...Section II Installation Wiring 16 Control board terminal layout ...
Страница 167: ......
Страница 175: ......