Section V. Parameter Function Table
56
Fig. 5-8 Three-line control mode 1
Among them
:
SB1
:
Stop button
SB2
:
Forward rotation button
SB3
:
Reverse rotation button
3
:
Three-line mode2
In this operation mode, X3 terminal is the enable terminal, Direction by the state of the X2 to decide,while X1
terminal function is to determine running direction. The descriptions on the terminal running command are as
shown as below
:
Terminal
Set value
Description
X1
1
Forward(FWD)
X2
2
Reverse(REV)
X3
3
Three-line running control
When in the need of running, users should first connect X3 terminal. X1 pulse rising edge gives running
command signal, while X2 status gives running direction signal.
When in the need of stop, user should disconnect DIn terminal to meet the need. Among them, X1, X2,
X3 are multi-function input terminals of X1~X10. X1 is of pulse valid, while X2, X3is of level valid.
0 invalid. 1 valid. X arbitrarily
SB1
SB2
K
Command
0
X
X
Stop
1
1
0
Forward(FWD)
1
1
1
Reverse(REV)
Fig. 5-9 Three-line control mode 2
HV610C
X2 (REV)
COM
X1(FWD)
X3 3-line running control
SB2
SB1
K
HV610C
X2 (REV)
COM
X1 (FWD)
X3 3-line running control
SB2
SB1
SB3