Section IV. Keyboard Operation
21
4.2 Display Interface
Modification of function parameter, monitoring of inverter operation, control of inverter
operation (start and stop) can be performed through the operation panel.Its shape and function
area are shown as below
:
Fig. 4-2.1
4.2.1 Indicator light indicates run
RUN: When the light is on, it indicates that the frequency inverter is in operation, and when
the light is off, it indicates that the frequency inverter is in shutdown state
LOCAL/REMOT: Keyboard operation, terminal operation and remote operation
(communication control) indicator light
FWD/REV: Positive and negative rotation indicator light, which indicates that it is in reverse
rotation when the light is on
TUNE/TC: Tuning / torque control / fault indicator light, light on indicates torque control
mode, light slow flashing indicates tuning state, and light flash indicates fault
state.
The unit indicator lamp is used to indicate the unit of the current
display data (○ marks off, ● marks on). There are the following units:
Hz frequency unit
A current unit
V voltage unit
RMP rotational speed unit
% percentage