Section V. Parameter Function Table
76
During acceleration process, if running frequency is less than F8.25 ,then choose acc. time2. If
running frequency is greater than F8.25, choose acc. time 1.
During deceleration process, if running frequency is greater than F8.26, then choose dec. time 1. If
running frequency is less than F8.26 , choose dec. time 2.
Output frequency
Hz
Acc. time2
Acc. time1
Dec. time1
Dec. time2
t
Setting frequency
P8.25
P8.26
Fig.5-19 Acc./dec. Time switching schematic diagram
F8.27
Terminal jog priority
Invalid
0
0
☆
Valid
1
It is used to set if terminal jog function has the highest priority.
When F8.27 is valid, if jog command occurring during running , inverter will switch to jog running
mode.
F8.28
Frequency detection
value(FDT2)
0.00Hz~Maximum frequency
50.00Hz
☆
F8.29
Frequency detection hysteresis
value(FDT2)
0.0%~100.0%(FDT2 level)
5.0%
☆
This frequency detection function and FDT1 function are exactly the same, for details please refer to
FDT1 , namely function codes F8.19, F8.20 description.
F8.30
Random frequency arrival
detection value1
0.00Hz~Maximum frequency
50.00Hz
☆
F8.31
Random frequency arrival
detection range1
0.0%~100.0%(Maximum frequency)
0.0%
☆
F8.32
Random frequency arrival
detection value2
0.00Hz~Maximum frequency
50.00Hz
☆
F8.33
Random frequency arrival
detection range2
0.0%~100.0%(Maximum frequency)
0.0%
☆