Section V. Parameter Function Table
41
Digital setup frequency source
1
AI1
2
AI2
3
AI3
4
PULSE pulse setup(X5)
5
MS command
6
Simple PLC
7
PID
8
Communication setup
9
100bit
Communication command binding
frequency source selection
Without bound
0
Digital setup frequency source
1
AI1
2
AI2
3
AI3
4
PULSE pulse setup(X5)
5
MS command
6
Simple PLC
7
PID
8
Communication setup
9
It defines bound combination between 3 running command channels and 9 frequency setup
channels, which is easy to achieve synchronous switching.
Frequency setup channels above have the same definition with F0.03 “main frequency source X
selection”, please refer to F0.03 for details. Different running command channels can bind the same
frequency setup channel. When the command source is valid during command source & frequency
source binding, set frequency source of F0.03~F0.07 is invalid.
F0.28
Communication protocol
selection
Modbus RTU
0
0
☆
Reserved
1
Reserved
2