Appendix I H5RS485 Card & RS485Communication Protocol
132
0004
:
Constant speed over current
0005
:
Speed-up over voltage
0006
:
Speed-DOWN over voltage
0007
:
Constant speed over voltage
0008
:
Buffer resistance overload fault
0009
:
Under-voltage fault
000A
:
Inverter overload
000B
:
Motor overload
000C
:
Input phase lost
000D
:
Output phase lost
000E
:
Module overheating
000F
:
External fault
0010
:
Communication fault
0011
:
Contactor fault
0012
:
Current detection fault
0013
:
Motor tuning fault
0014
:
Encoder/PG card fault
0015
:
Parameter read and write fault
0016
:
Inverter hardware fault
0017
:
Motor earthing short-circuit fault
Communication fault information describing data (fault code)
:
Communication fault address
Fault function description
8001
0000
:
No fault
0001
:
Password error
0002
:
Command code error
0003
:
CRC check error
0004
:
Invalid address
0005
:
Invalid parameter
0006
:
Parameter change invalid
0007
:
The system is locked
0008
:
Operating EEPROM
Fd group communication parameters description
Fd.00
Baud rate
Factory default value
6005
Setup range
1 bit
:
MODUBS baud rate
0
:
300BPS
1
:
600BPS
2
:
1200BPS
3
:
2400BPS
4
:
4800BPS
5
:
9600BPS
6
:
19200BPS
7
:
38400BPS
8
:
57600BPS
9
:
115200BPS
This parameter is used to set the data transfer rate between the host computer and the
inverter. Caution
:
The baud rate of the position machine and the inverter must be consistent.
Or,communication is impossible.The higher the baud rate is,the faster the communication is.
Fd.01
Data format
Factory default value
0
Setup range
0
:
No check
:
data format <8,N,2>
1
:
Even parity check
:
data format <8,E,1>
2
:
Odd parity check
:
data format <8,O,1>
3
:
No check
:
data format <8-N-1>
The data format of the position machine and the inverter setup must be consistent,
Otherwise communication is impossible.
Fd.02
Local address
Factory default value
1
Setup range
1~247
,
0 is broadcast address.