Section IV. Keyboard Operation
22
4.3 Examples for parameter setting
4.3.1 Methods of checking and modifying function codes
The operation panel of this series of frequency inverters uses a three-level menu structure
to set parameters and other operations.
The three-level menus are: function parameter group (I - level menu) → function code (II -
level menu) → function code setting value (level III menu).
Description: press PRG key or enter key to return to the level II menu when operating the
level II menu. The difference between the two is: press enter to save the setting parameters and
return to the secondary menu, and automatically transfer to the next function code; while
pressing PRG key is to abandon the current parameter modification and directly return to the
secondary menu of the current function code serial number.
Example: example of setting function code F3 - 02 to 15.00 Hz from 10.00 Hz
In the level III menu state, if the parameter does not flash, it indicates that the function code
cannot be modified. Possible reasons are:
This function code is an unmodified parameter, such as frequency inverter type, actual
detection parameter, operation record parameter, etc.
This function code cannot be modified in the running state. It can only be modified after
shutdown.